XD3-6KTL – Single Phase Hybrid Inverter

Efficient Higher Revenue

  • Max. Efficiency 97.5%
  • Max. PV Input Voltage 600V
  • 150% Peak Output Power
  • 2 MPP Trackers, 150% DC Input Oversizing
  • Max. PV Input Current 16A, Compatible with High Power Modules

Intelligent Simple O&M

  • IP66 Protection Degree: support outdoor installation
  • Smart I-V Curve Diagnosis Function: locate PV string faults accurately and automatically detect faults
  • DC & AC Type II SPD: prevent lightning damage
  • Battery Reverse Connection Protection

Flexible Abundant Configuration

  • Plug & Play, EPS Switching Under 10ms
  • Compatible with Lead-acid and Lithium Batteries
  • Max. 6 units Inverters Parallel
  • AFCI Function (Optional): when an arc-fault is detected the inverter immediately stops operation

Description

Specification

XD3KTL XD3K6TL XD4KTL XD4K6TL XD5KTL XD6KTL
Input (PV)
Max. PV Input Power 4.5kW 5.4kW 6kW 6.9kW 7.5kW 9kW
Max. PV Input Voltage 600V 600V 600V 600V 600V 600V
Start-up Voltage 100V 100V 100V 100V 100V 100V
Rated Voltage 360V 360V 360V 360V 360V 360V
MPPT Voltage Range 100V – 550V 100V – 550V 100V – 550V 100V – 550V 100V – 550V 100V – 550V
Number of MPPT Trackers 2 2 2 2 2 2
Number of String per MPPT 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1
Max. Current per MPPT 16A 16A 16A 16A 16A 16A
Max. Short Circuit Current per MPPT 24A 24A 24A 24A 24A 24A
Output (AC)
Rated Output Power 3kVA 3.68kVA 4kVA 4.6kVA 5kVA 6kVA
Max. Output Power 3.3kVA 3.68kVA 4.4kVA 4.6kVA 5.5kVA 6kVA
Max. Output Current 15A 16A 20A 20.9A 22.7A 27.3A
Rated Voltage 230V 230V 230V 230V 230V 230V
Rated Frequency 50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz
THDi(@Rated Power) < 3% < 3% < 3% < 3% < 3% < 3%
Power Factor 0.8 leading – 0.8 lagging 0.8 leading – 0.8 lagging 0.8 leading – 0.8 lagging 0.8 leading – 0.8 lagging 0.8 leading – 0.8 lagging 0.8 leading – 0.8 lagging
Output (EPS)
Max. Output Power 3kVA 3.68kVA 4kVA 4.6kVA 5kVA 6kVA
Max. Output Current 15A 16A 20A 20.9A 22.7A 27.3A
Peak Output Power, Time 4.5kW, 10s 5.5kW, 10s 6kW, 10s 6.9kW, 10s 7.5kW, 10s 7.5kW, 10s
Rated Voltage, Frequency 230V, 50Hz 230V, 50Hz 230V, 50Hz 230V, 50Hz 230V, 50Hz 230V, 50Hz
THD(@Rated Power) < 3% < 3% < 3% < 3% < 3% < 3%
Switch Time < 10ms < 10ms < 10ms < 10ms < 10ms < 10ms
Battery
Battery Type Lithium, Lead-acid
Battery Voltage Range 40V – 60V
Max. Charge / Discharge Current 100A
Communication CAN
Efficiency
Max. Efficiency 97.50%
EU Efficiency 97.20%
Battery Charge / Discharge Efficiency 95.00%
Protection
DC Switch Yes
DC Reverse Polarity Protection Yes
Anti-islanding Protection Yes
AC Short Circuit Protection Yes
Residual Current Monitoring Yes
Insulation Resistance Monitoring Yes
Ground Fault Monitoring Yes
Over Current / Voltage Protection Yes
Battery Soft Start Protection Yes
Surge Protection Type II
AFCI Protection Optional
Communication
Display LCD
Communication RS485 / CAN / WIFI / 4G / LAN / Bluetooth
Standard Compliance
Certification IEC/EN 62109-1/2, IEC/EN 61000-6-1/3, IEC61727/IEC62116, EN50549, CEI-0-21, C10/C11, VDE4105, VDE0126, G98/G99, RD244, UNE217001, UNE217002, AS4777, NRS097-2-1
General Data
Dimension (W x H x D) 490 x 395 x 200 mm
Weight 20kg
Operating Temperature Range -30°C ~ +60°C
Cooling Method Natural
Protection Degree IP66
Max. Operating Altitude 4000m
Noise ≤ 25dB
Relative Humidity 0-100%
Self-consumption < 10W
Topology High Frequency Insulation (For battery)