Description
Construction
Component | Specification |
---|---|
Conductor | Aluminium class 2 according to EN 60228 and IEC 60228. Optionally, with longitudinal water tightness (cable type -2OL). |
Conductor screen | Screen over the conductor, made of thermosetting semiconductor material. |
Insulation | Cross-linked polyethylene type XLPE according to IEC 60502-2, natural colour. Cross linked in catenary line with nitrogen atmosphere through a triple layer extrusion process. |
Insulation screen | Screen over the insulation, made of thermosetting and strippable semiconductor material. |
Metallic screen | Copper wires and copper tape screen, with a minimum cross-section of 16mm². |
Longitudinal water tightness | Hygroscopic tape completely covering the screen (cable type –OL and -2OL). |
Outer sheath | Polyethylene type ST7 according to IEC 60502-2. Red colour. |
Characteristics
Electrical performance
Feature | Specification |
---|---|
Medium Voltage | 6/10 (12) kV 8,7/15 (17,5) kV 12/20 (24) kV 18/30 (36) kV |
Thermal performance
Feature | Specification |
---|---|
Maximum conductor temperature | 90°C |
Maximum short-circuit temperature | 250°C (max 5 s). |
Minimum service temperature | -15°C |
Fire performance
Feature | Specification |
---|---|
Reaction to fire CPR | Fca according to EN 50575. |
Halogen free | According to EN 60754-1 / IEC 60754-1. |
Low corrosive gases emission | According to EN 60754-2 / IEC 60754-2. |
Mechanical performance
Feature | Specification |
---|---|
Minimum bending radius | 15x cable diameter. |
Abrasion resistant | Yes |
Tear resistant | Yes |
Environmental performance
Feature | Specification |
---|---|
UV Resistant | According to UNE 211605. |
Installation conditions
Condition | Details |
---|---|
Open Air | Suitable |
Buried | Suitable |
In conduit | Suitable |