Model |
3TL |
6TL |
INPUT (DC) |
Recommended PV field power range |
3.09 – 4.5 kWp |
6.18 – 9 kWp |
MPPT voltage range |
50 – 490 V |
70 – 540 V |
Initial input voltage |
70 V |
90 V |
Maximum voltage |
500 V |
550 V |
Nominal input voltage |
360 V |
360 V |
Maximum short-circuit current |
20 A |
40 A (2*20 A) |
Maximum current |
15 A |
30 A (2*15 A) |
Inputs with PV connectors |
1 |
2 (1/1) |
Number of MPPTs |
1 |
2 |
OUTPUT (AC) |
Nominal power |
3 kW |
6 kW |
Maximum apparent power |
3.3 kVA |
6 kVA |
Maximum active power (PF = 1) (1) |
3.3 kW |
6 kW |
Maximum output current (1) |
15 A |
27.3 A |
Nominal voltage |
220 / 230 V |
220 / 230 V |
Voltage range (2) |
160 – 300 V (Adjustable) |
160 – 300 V (Adjustable) |
Frequency |
50 / 60 Hz |
50 / 60 Hz |
Grid type |
TT / TN |
TT / TN |
Power factor |
> 0.99 Nominal power (adjustable 0.8 LD – 0.8 LG) |
> 0.99 Nominal power (adjustable 0.8 LD – 0.8 LG) |
THD |
< 3% at nominal power |
< 3% at nominal power |
EFFICIENCY |
Maximum efficiency |
97% |
97% |
Euro efficiency |
96% |
96.10% |
GENERAL INFORMATION |
Cooling system |
Natural ventilation |
Natural ventilation |
Nighttime consumption |
< 10 W |
< 10 W |
Ambient temperature |
-25°C to 60°C |
-25°C to 60°C |
Relative humidity (no condensation) |
0 – 100% |
0 – 100% |
Protection class |
IP65 |
IP65 |
CE marking |
Yes |
Yes |
Noise emissions |
30 dB |
30 dB |
Maximum operating altitude |
4,000 m |
4,000 m |
EMC and safety standards |
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2 |
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2 |
Grid connection standards |
IEC 61727:2004, IEC 62116:2014, EN 50549-1:2019, UNE 217002:2020, UNE 217001:2020, NTS SEPE 2.1 type A, CEI 0-21 v1 November 2022 (including Annex B), VDE-AR-N 4105:2018 |
IEC 61727:2004, IEC 62116:2014, EN 50549-1:2019, UNE 217002:2020, UNE 217001:2020, NTS SEPE 2.1 type A, CEI 0-21 v1 November 2022 (including Annex B), VDE-AR-N 4105:2018 |
Integrated Elements |
DC switch |
Yes |
Yes |
Anti-islanding protection |
Yes |
Yes |
AC overcurrent protection |
Yes |
Yes |
AC short-circuit protection |
Yes |
Yes |
DC reverse connection |
Yes |
Yes |
DC and AC surge protectors, type III |
Yes |
Yes |
Insulation detection |
Yes |
Yes |
Leakage current protection |
Yes |
Yes |